Close
Go To Macao Polytechnic University

2020/2021

Application of error function in dead-end/cross-flow microfiltration mode

IOP Conference Series: Earth and Environmental Science*, 2021, 647(1): article no. 012007

Author(s)Ge Hu,
Chenyin Zhong,
Zhan Wang,
Xi Wang
Summary

In this study, error function was used to analyze the membrane fouling behavior (flux decay) for bovine serum album (BSA) solution in dead-end mode and for kaolin suspension in cross-flow mode under constant pressure. The results showed that the predictions of error function had good agreements with experimental data both in dead-end mode and cross-flow mode. Meanwhile, both higher concentration and higher TMP could accelerate the membrane fouling rate. In addition, the parameter k in error function decreased with the increase of concentration or TMP. Thus, smaller parameter k represented more serious membrane fouling.


* Also listed in Scopus.